- Product Details
Main functions:
Xenon Lamp Test Chamber Corresponding standard:
ASTM G155-05a Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials1
Xenon Test Chamber Applicable industries:
Applied to control the product quality, such as electronic, plastic products, electrical appliances, instruments, food, vehicles, metals, chemicals, building materials, aerospace, medical care and so on.
Technical parameter:
Model | HZ-2011 Xenon Test Chamber | |
Testing room D×W×H | 500*600*500mm | |
Index | Temperature range | RT+10°C~80°C |
Humidity range | 65~98%R·H | |
Spray time | 1~9999min, adjustable | |
Spray cycle | 1-240min, interval adjustable | |
Spectral wavelength | 290nm~800nm (60w/m2) | |
Light source | Xenon lamp (air-cooled) | |
Xenon lamp power | 1kw, 6kw (longevity: 1600H) | |
Temperature and humidity control | Time controller | Import controller from Moeller |
Accurate range | Temperature: ±0.1°C / humidity: ±0.1°CR·H | |
Sensor | Platinum resistance Pt100Ω/mv | |
Heating system | Independent system, nickel chromium alloy electric heating type heater | |
Humidity system | Stainless steel, external Isolated humidifier | |
Blackboard temperature | Bimetal thermometer blackboard 55°C~75°C | |
Water supply | Humidification water supply with automatic control, xenon lamp cooled by water recycling | |
Temperature controller | Import controller | |
Humidity | Irradiation: 30%~65%RH darkly: up to 90%RH | |
Cycle system | Low-noise air-conditioning-type motors, multi-leaf-type centrifugal wind wheel | |
Material | Outside material | Advanced spray color plate /SUS304 stainless steel |
Inside material | SUS304 stainless steel | |
Sample holder material | SUS304 stainless steel | |
Insulation | High and low temperature aging of silicone rubber | |
Standard | A set of radiation-proof glass window, dynamic testing sample shelf 1, xenon lamp tube 2 | |
Protector | Leakage, short circuit, over-temperature, water shortages, motor overheating, over-current protection. | |
Power | AC380V±10% 50±0.5HZ, Three-phase five-wire system | |
Environmental temperature | ±5°C~+30°C ≤85%R·H |