Lixian Instrument Scientific Co., Ltd
  • Liquid Products Flash Point Tester Equipment HZ-9035
Liquid Products Flash Point Tester Equipment HZ-9035
Liquid Products Flash Point Tester Quality assurance, verification of flammable components of the liquid products.Safety tests to determine need someone to monitor the transport and disposal of liquid.Fuel dilution to determine the percentage of fuel in the engine crankcase, add essential oils to make the engine restart.Quick test a small sample. Less than 100 degrees Celsius, 2 ml of the sample of Fp value of the test is 1 minute.
  • Tel:+86 13711888650
  • Product Details

Equipment Summary:

Quality assurance, verification of flammable components of the liquid products.

Safety tests to determine need someone to monitor the transport and disposal of liquid.

Fuel dilution to determine the percentage of fuel in the engine crankcase, add essential oils to make the engine restart.

Quick test a small sample

Less than 100 degrees Celsius, 2 ml of the sample of Fp value of the test is 1 minute. You can run 10 tests, within the specified time machine to take the specified method of execution. 2ml/4ml samples only a small part of the large sample. Thus reducing the sampling problem, increase the security.

Digital circuit allows simple adjustment to automatically adjust the test temperature, pressure preset switch while rotating the temperature control knob until the target temperature, the temperature of the sample cup is automatically displayed on the LCD monitor.

Two modes: Closed type for flash point testing: opening for flammability test.

 Easy to use: the flash point value according to the following three-step simple operation can be drawn:

Adjust the monitor to the target test temperature:

Injection of 2 or 4 mL sample to a sample cup, and so on for 1-2 minutes, to be evaporated balance.

The introduction of the test flame, observed that there is no flash point, the test is completed.

Comparison

Independent laboratory tests show that the ASTM D 3828 test method is the use of the instrument with the same results as the other flash point test method. ASM D-2 Joint Declaration test ASTM D3828 test method has the following correlation coefficient:

 D 3828 (Rapid Tester?) VS. D56 (Tag) = 0.9949

D 3828 (Rapid Tester?) VS. D 93 (Pensky-Martens) = 0.9943

D 56 vs. D 93 = 0.9926

 

Specifications:

This instrument is a semi-automatic tool to determine the temperature of the flammable liquid flash point / flammability. The closed test measure from room temperature to 300 ° C is automatically controlled by preset target temperature. Digital display. NIST traceable thermometer, fuel tank and electronic timer is standard.

Consistent with the following criteria:

ASTM D 3278, ASTM D 3828 ASTM D 4206 BS 3900 Par All, BS 3900 Part A13, BS 3900 part A14 CPSC CFR 16-1500.43a, DOT CFR 49-173.115, IATA Resolution 618

Additional:

IP 303, ISO 3679, ISO 3680, OSHA 29CFR 1910-106, OSHA 29CFR 1910-1200.

Reproducibility of the data (RT-01): 0.50 @ 70 ℃, 2.00 @ 150 ° C

Repeatability: 2.00 @ 70 ° C 7.50 @ 150 ° C

Test time: 1min below 100 ℃, 2min above 100 ℃

The main parameters:

Cup type: RT-01 closed, the RT-02 opening temperature range:-30t0300 ° C (-220 to 5720F)

Cup Material: aluminum (optional stainless steel) cooling the ambient temperature need cooling block RT-05505

Size: 38.1 * 8.64 * 16.25cm

Display: LCD, NIST traceable mercury glass thermometer

Net weight: 4.6kg

Power supply: 115V, 50, 60 HZ, 230V, 50/60Hz


9035A_1.jpg