- Product Details
Detailed Configurations As Follows
Compound Salt Spray Test machine With Humidity Control Material
(A) testing room using PVC polyvinyl chloride plate (from Taiwan), acid-resisting and alkali-resisting, cleaning easier.
(B) cover of testing room using acrylic panels (imported organic glass), the thickness is 5mm.
(C) reagents added bottles attached with water gauge, cleaning easy and not easy to break.
(D) saturated air barrels is made of SUS # 304 stainless steel.
(E) testing room to adopt indexing frame, can be arbitrarily adjust the angle, Surrounded by fog and placed more piece .
Corresponding Standard
2.GB/T 2423.18-2000 salt spray test
3.GB/T 10125-1997 salt spray test
4.ASTM.B117-97 salt spray test
5.JIS H8502 salt spray test
6.IEC68-2-11 salt spray test
7.IEC68-2-52 1996 salt spray test
8.GB.10587-89 salt spray test
9.CNS.4158 salt spray test
10.CNS.4159 CASS Accelerated acetic acid copper salt spray test
11..GB/T 12967.3-91 CASS Accelerated acetic acid copper salt spray test
12. ASTM B117 Standard Practice for Operating Salt Spray (Fog) Apparatus
13.SAE J2334 Laboratory Cyclic Corrosion Test
14.IEC 60945-8.12 Maritime navigation and radiocommunication equipment and systems – General requirements – Methods of testing and required test results
According to CNS JIS ASTM GB2423.19 specifications, can be set constant temperature to control
(A) Salt spray test: NSS, ACSS
1. testing room : 35 ℃ ± 1 ℃
2 saturated air barrels : 47 ℃ ± 1 ℃
(B) anti-corrosion test: CASS (copper acetate)
1.testing room: 50 ℃ ± 1 ℃
2. saturated air barrels: 63 ℃ ± 1 ℃
Technical Parameters
Model | HZ-2002A-270L | HZ-2002B-480L | HZ-2002C-800L |
Inside box size(cm) | 90x60x50 | 120x80x50 | 160x100x50 |
Outside box size(cm) | 141x88x128 | 190x110x140 | 230x130x140 |
Testing room temperature | Salt test (NSS ACSS)35℃±1℃/ Corrosion Test (CASS)50℃±1℃ | ||
Pressure barrel temperature | Salt test (NSS ACSS)47℃±1℃/ Corrosion Test (CASS)63℃±1℃ | ||
Brine temperature | 25℃±1℃ ~60℃±1℃ | ||
Testing room Capacity | 270L | 480L | 800L |
Brine tank capacity | 25L | 40L | 55L |
Salt concentration | The concentration of sodium chloride 5% or the 5% concentration of sodium chloride add 0.26g per liter of copper chloride (CuCl2 2H2O) | ||
Air pressure | 1.00±0.01kgf/cm2 | ||
Spray volume | 1.0~2.0ml/80cm2/h (working at least 16 hours, and then take the average) | ||
Testing room relative humidity | 85% above | ||
PH | 6.5~7.2 3.0~3.2 | ||
Spray form | Programmable spray (Including continuous and intermittent spray) | ||
power | AC220V1Φ10A | AC220V1Φ15A | AC220V1Φ20A |
Controller Interface and Explain